• FA23 Water Flow Sensor
  • FA23 Water Flow Sensor
FA23 Water Flow Sensor
FA23 Water Flow Sensor
+

Share to

FA23 Water Flow Sensor

Application: This specification applies to flow sensors used in water heaters, wall-hung boilers or similar equipment.

Still deciding? Get samples first,  Contact US !

View similar products

Tag list

  • Product description
  • FA23 Water Flow Sensor

    General Specifications

    Application: This specification applies to flow sensors used in water heaters, wall-hung boilers or similar equipment.
    Operating ambient temperature: 0 ~ +80 ℃
    Operating medium temperature: 0 ~ +60 ℃, no icing.
    Operating and test medium: Tap water or compatible liquids.
    Test conditions: Unless otherwise specified, the tests shall be performed under the following conditions:

    Ambient temperature: 5 ~ 35 ℃
    Relative humidity: 45 ~ 85%
    Atmospheric pressure: 86 ~ 106 kPa (860 ~ 1060 mbar)

    Appearance, Structure and Dimension
    Appearance: The product shall have a good appearance, free from defects such as rust and cracks.
    Structure and Dimensions: Please refer to the finished product drawing.
    Product Marking: Please refer to the finished product drawing.

    Rated Parameters and Durability

    Rated Operating Voltage: 3 VDC (2.4 ~ 3.3 VDC)
    Maximum Operating Frequency: 500 Hz
    Maximum Switching Current: 0.3 A DC
    Maximum Switching Voltage: 100 VDC
    Contact Resistance: < 100 mΩ
    Insulation Resistance: > 100 MΩ when 500 VDC is applied between leads and housing
    Long-term Working Medium Pressure: Max. 0.8 MPa
    Withstand Pressure: Max. 1.75 MPa
    Frequency-Flow Equation: F = 8.1Q − 3 where: 
    F (Frequency): Hz Q (Flow Rate): L/min Flow Tolerance: 1 ~ 3 L/min: ± 2 Hz 4 ~ 5 L/min: ± 10% Above 6 L/min: ± 5%

    Rated Flow Range: 1 ~ 25 L/min

    Notes
    Do not operate the product dry for a prolonged period, as this may damage the rotor.
    Do not use the product under conditions exceeding its rated ambient temperature and rated medium temperature, otherwise it may cause damage to the product.
    If the medium (water) freezes, thaw it slowly at room temperature. Replace the flow sensor before putting the equipment back into use; otherwise, uncertain effects or losses may occur.

FA23 Water Flow Sensor

Application: This specification applies to flow sensors used in water heaters, wall-hung boilers or similar equipment.

Still deciding? Get samples first,  Contact US !

Products Category

Tag list

Inquire Now

Note: Please leave your email address, our professionals will contact you as soon as possible!